1.2.3.2.5 Configure 'No auto-restart with logged on users for scheduled automatic updates installations'

Information

This policy setting specifies that Automatic Updates will wait for computers to be restarted by the users who are logged on to them to complete a scheduled installation. If you enable the No auto-restart for scheduled Automatic Updates installations setting, Automatic Updates does not restart computers automatically during scheduled installations. Instead, Automatic Updates notifies users to restart their computers to complete the installations. You should note that Automatic Updates will not be able to detect future updates until restarts occur on the affected computers. If you disable or do not configure this setting, Automatic Updates will notify users that their computers will automatically restart in 5 minutes to complete the installations. The possible values for the No auto-restart for scheduled Automatic Updates installations setting are: . Enabled . Disabled . Not Configured Note: This setting applies only when you configure Automatic Updates to perform scheduled update installations. If you configure the Configure Automatic Updates setting to Disabled, this setting has no effect. Sometimes updates require updated computers to be restarted to complete an installation. If the computer cannot restart automatically, then the most recent update will not completely install and no new updates will download to the computer until it is restarted.

Solution

Configure the following Group Policy setting in a manner that is consistent with the security and operational requirements of your organization-

Computer Configuration\Administrative Templates\Windows Components\Windows Update\No auto-restart with logged on users for scheduled automatic updates installations

Impact- If you enable this policy setting, the operating systems on the servers in your environment will restart themselves automatically. For critical servers this could lead to temporary but unexpected, DoS conditions.

See Also

https://workbench.cisecurity.org/files/42

Item Details

Category: SYSTEM AND INFORMATION INTEGRITY

References: 800-53|SI-2(5), CCE|CCE-3277-1

Plugin: Windows