Information
The log_timezone setting specifies the time zone to use in timestamps within log messages. This value is cluster-wide, so that all sessions will report timestamps consistently. Unless directed otherwise by your organization's logging policy, set this to either GMT or UTC.
Rationale:
Log entry timestamps should be configured for an appropriate time zone as defined by your organization's logging policy to ensure a lack of confusion around when a logged event occurred.
Solution
Execute the following SQL statement(s) to remediate this setting:
postgres=# alter system set log_timezone = 'GMT';
ALTER SYSTEM
postgres=# select pg_reload_conf();
pg_reload_conf
----------------
t
(1 row)
Default Value:
By default, the PGDG packages will set this to match the server's timezone in the Operating System.