F5BI-AP-000073 - The BIG-IP APM module must uniquely identify and authenticate organizational users (or processes acting on behalf of organizational users) when connecting to virtual servers.

Information

To assure accountability and prevent unauthenticated access, organizational users must be identified and authenticated to prevent potential misuse and compromise of the system.

Organizational users include organizational employees or individuals the organization deems to have equivalent status of employees (e.g., contractors). Organizational users (and any processes acting on behalf of users) must be uniquely identified and authenticated for all accesses except the following:

1) Accesses explicitly identified and documented by the organization. Organizations document specific user actions that can be performed on the information system without identification or authentication; and

2) Accesses that occur through authorized use of group authenticators without individual authentication. Organizations may require unique identification of individuals in group accounts (e.g., shared privilege accounts) or for detailed accountability of individual activity.

This requirement applies to ALGs that provide user proxy services, including identification and authentication. This service must use the site's directory service (e.g., Active Directory). Directory services must not be installed onto the gateway.

NOTE: Nessus has provided the target output to assist in reviewing the benchmark to ensure target compliance.

Solution

If user access control intermediary services are provided, configure an access policy in the BIG-IP APM module to uniquely identify and authenticate organizational users (or processes acting on behalf of organizational users).

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_F5_BIG-IP_Y24M01_STIG.zip

Item Details

Category: IDENTIFICATION AND AUTHENTICATION

References: 800-53|IA-2, CAT|II, CCI|CCI-000764, Rule-ID|SV-215718r557355_rule, STIG-ID|F5BI-AP-000073, STIG-Legacy|SV-74457, STIG-Legacy|V-60027, Vuln-ID|V-215718

Plugin: F5

Control ID: c528e7afc5596d695010c2d7366d366b61b0c38e357ef38937df2a9bf10663cd