F5BI-DM-000003 - The BIG-IP appliance must limit the number of concurrent sessions to the Configuration Utility to 10 or an organization-defined number - 1 for each administrator account and/or administrator account type.

Warning! Audit Deprecated

This audit has been deprecated and will be removed in a future update.

View Next Audit Version

Information

Device management includes the ability to control the number of administrators and management sessions that manage a device. Limiting the number of allowed administrators and sessions per administrator is helpful in limiting risks related to DoS attacks.

This requirement addresses concurrent sessions for administrative accounts and does not address concurrent sessions by a single administrator via multiple administrative accounts. The maximum number of concurrent sessions should be defined based upon mission needs and the operational environment for each system.

Solution

Configure the BIG-IP appliance either to limit the number of concurrent sessions to 10 or an organization-defined number.

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_F5_BIG-IP_11-x_Y23M11_STIG.zip

Item Details

References: CAT|II, CCI|CCI-000054, Rule-ID|SV-217381r879511_rule, STIG-ID|F5BI-DM-000003, STIG-Legacy|SV-74521, STIG-Legacy|V-60091, Vuln-ID|V-217381

Plugin: F5

Control ID: 85a258977cff5e35046b54817243adeca746e356902f86e005d9b64e7fae3618