WA000-WI100 IIS7 - The File System Object component must be disabled.

Warning! Audit Deprecated

This audit has been deprecated and will be removed in a future update.

View Next Audit Version

Information

Some Component Object Model (COM) components are not required for most applications and should be removed if possible. Most notably, consider disabling the File System Object component; however, this will also remove the Dictionary object. Be aware some programs may require this component (e.g., Commerce Server), so it is highly recommended this be tested completely before implementing on the production web server.

Solution

Run the following command, with adminstrator priviledges, to unregister the File System Object: regsvr32 scrrun.dll /u.

Note: Make sure the Administrators group owns and has full permissions to the registry value HKCR\TypeLib\{420B2830-E718-11CF-893D-00A0C9054228}\1.0\0\win32 before trying to unregister the dll. Without the Administrators group owning and having full control of this key, the unregister command will error.

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_MS_IIS_7-0_STIG.zip

Item Details

Category: CONFIGURATION MANAGEMENT

References: 800-53|CM-7, CAT|II, CSCv6|9.1, Rule-ID|SV-46359r4_rule, STIG-ID|WA000-WI100_IIS7, Vuln-ID|V-13700

Plugin: Windows

Control ID: d408bc8fc16e32f550d444def9304177db883533b36293ffa748ee9dbd6a7012