WA000-WI6230 - The production web-site must configure the Maximum Query String limit.

Warning! Audit Deprecated

This audit has been deprecated and will be removed in a future update.

View Next Audit Version

Information

By setting limits on web requests, it helps to ensure availability of web services and may also help mitigate the risk of buffer overflow type attacks. The Maximum Query String Request Filter describes the upper limit on allowable query string lengths. Upon exceeding the configured value, IIS will generate a Status Code 404.15.

Solution

1. Open the IIS Manager.
2. Click the site name under review.
3. Double-click the Request Filtering icon.
4. Click Edit Feature Settings in the Actions Pane.
5. Set the Maximum Query String value to 2048.

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_MS_IIS_7-0_STIG.zip

Item Details

Category: SYSTEM AND INFORMATION INTEGRITY

References: 800-53|SI-10, CAT|II, Rule-ID|SV-32694r3_rule, STIG-ID|WA000-WI6230, Vuln-ID|V-26043

Plugin: Windows

Control ID: 05824052d81847b7949457b08695ad55e0713a3815ecfaee8f07f61e7e28ba5f