IISW-SI-000257 - The application pools pinging monitor for each IIS 8.5 website must be enabled.

Information

Windows Process Activation Service (WAS) manages application pool configurations and may flag a worker process as unhealthy and shut it down. An application pool's pinging monitor must be enabled to confirm worker processes are functional. A lack of response from the worker process might mean the worker process does not have a thread to respond to the ping request, or it is hanging for some other reason. The ping interval and ping response time may need adjustment to gain access to timely information about application pool health without triggering false, unhealthy conditions; for example, instability caused by an application.

Solution

Open the IIS 8.5 Manager.

Click the 'Application Pools'.

Perform for each Application Pool.

Highlight an Application Pool to review and click 'Advanced Settings' in the 'Actions' pane.

Scroll down to the 'Process Model' section and set the value for 'Ping Enabled' to 'True'.

Click 'OK'.

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_MS_IIS_8-5_Y23M10_STIG.zip

Item Details

Category: CONFIGURATION MANAGEMENT

References: 800-53|CM-6b., CAT|II, CCI|CCI-000366, Rule-ID|SV-214490r879887_rule, STIG-ID|IISW-SI-000257, STIG-Legacy|SV-91573, STIG-Legacy|V-76877, Vuln-ID|V-214490

Plugin: Windows

Control ID: 8248b7ada83246ad642f720e9791499d8bf1931d63c1f7ef83915c4c7d0b1621