JUEX-NM-000430 - The Juniper EX switch must be configured to synchronize internal information system clocks using redundant authoritative time sources.

Warning! Audit Deprecated

This audit has been deprecated and will be removed in a future update.

View Next Audit Version

Information

The loss of connectivity to a particular authoritative time source will result in the loss of time synchronization (free-run mode) and increasingly inaccurate time stamps on audit events and other functions.

Multiple time sources provide redundancy by including a secondary source. Time synchronization is usually a hierarchy; clients synchronize time to a local source while that source synchronizes its time to a more accurate source. The network device must utilize an authoritative time server and/or be configured to use redundant authoritative time sources. This requirement is related to the comparison done in CCI-001891.

DoD-approved solutions consist of a combination of a primary and secondary time source using a combination or multiple instances of the following: A time server designated for the appropriate DoD network (NIPRNet/SIPRNet); United States Naval Observatory (USNO) time servers; and/or the Global Positioning System (GPS). The secondary time source must be located in a different geographic region than the primary time source.

Solution

Configure the network device to synchronize internal information system clocks with the primary and secondary time sources.

set system ntp authentication-key 1 type sha256
set system ntp authentication-key 1 value 'PSK'
set system ntp authentication-key 2 type sha1
set system ntp authentication-key 2 value 'PSK'
set system ntp server <address 1> key 1
set system ntp server <address 1> prefer
set system ntp server <address 2> key 2
set system ntp trusted-key 1
set system ntp trusted-key 2
set system ntp source-address <lo0 or OOBM address>