DO6751-ORACLE11 - The SQLNet SQLNET.ALLOWED_LOGON_VERSION parameter must be set to a value of 11 or higher - '$ORACLE_HOME/network/admin/sqlnet.ora SQLNET.ALLOWED_LOGON_VERSION > 11'

Information

Unsupported Oracle network client installations may introduce vulnerabilities to the database. Restriction to use of supported versions helps to protect the database and helps to enforce newer, more robust security controls.

Solution

Edit the SQLNET.ORA file to add or edit the entry:

SQLNET.ALLOWED_LOGON_VERSION = 11

Set the value to 11 or higher.

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_Oracle_Database_11g_Y21M10_STIG.zip

Item Details

Category: CONFIGURATION MANAGEMENT, SYSTEM AND INFORMATION INTEGRITY

References: 800-53|CM-7(5), 800-53|SI-2, CAT|II, Rule-ID|SV-24958r2_rule, STIG-ID|DO6751-ORACLE11, Vuln-ID|V-16057

Plugin: Unix

Control ID: eefa5f55b84222f2ff7b945b045a97291e7d78443d55fc81f3e48bd2ec417815