CASA-ND-000930 - The Cisco ASA must be configured to generate an immediate real-time alert of all audit failure events requiring real-time alerts - logging trap

Warning! Audit Deprecated

This audit has been deprecated and will be removed in a future update.

View Next Audit Version

Information

It is critical for the appropriate personnel to be aware if a system is at risk of failing to process audit logs as required. Without a real-time alert, security personnel may be unaware of an impending failure of the audit capability and system operation may be adversely affected.

Alerts provide organizations with urgent messages. Real-time alerts provide these messages immediately (i.e., the time from event detection to alert occurs in seconds or less).

Solution

Configure the Cisco ASA to send critical to emergency log messages to the syslog server as shown in the example below.

ASA(config)# logging host NDM_INTERFACE 10.1.48.10
ASA(config)# logging trap critical
ASA(config)# end

Note: The parameter critical can replaced with a lesser severity (i.e., error, warning, notice, informational).

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_Cisco_ASA_Y23M10_STIG.zip

Item Details

References: CAT|II, CCI|CCI-001858, Rule-ID|SV-239923r879733_rule, STIG-ID|CASA-ND-000930, Vuln-ID|V-239923

Plugin: Cisco

Control ID: 8a95a029a979771bef650f7adc37fe231b51a5a3a9945442ae9373e8c1465757