CISC-ND-000330 - The Cisco switch must be configured to generate audit records containing the full-text recording of privileged commands.

Information

Reconstruction of harmful events or forensic analysis is not possible if audit records do not contain enough information.

Organizations consider limiting the additional audit information to only that information explicitly needed for specific audit requirements. The additional information required is dependent on the type of information (i.e., sensitivity of the data and the environment within which it resides). At a minimum, the organization must audit full-text recording of privileged commands. The organization must maintain audit trails in sufficient detail to reconstruct events to determine the cause and impact of compromise.

Solution

Configure the Cisco switch to log all configuration changes as shown in the example below:

SW4(config)#archive
SW4(config-archive)#log config
SW4(config-archive-log-cfg)#logging enable
SW4(config-archive-log-cfg)#end

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_Cisco_IOS-XE_Switch_Y24M10_STIG.zip

Item Details

Category: AUDIT AND ACCOUNTABILITY

References: 800-53|AU-3(1), CAT|II, CCI|CCI-000135, Rule-ID|SV-220530r960909_rule, STIG-ID|CISC-ND-000330, STIG-Legacy|SV-110515, STIG-Legacy|V-101411, Vuln-ID|V-220530

Plugin: Cisco

Control ID: ca17134579e8073907fd7897f440bb6f48ce1e7e51129a7146ad68cb78220119