NET0812 - Two NTP servers are not used to synchronize time - 'First NTP Server'

Information

The network element must use two or more NTP servers to synchronize time.

Without synchronized time, accurately correlating information between devices becomes difficult, if not impossible. If you cannot successfully compare logs between each of your routers, switches, and firewalls, it will be very difficult to determine the exact events that resulted in a network breach incident. NTP provides an efficient and scalable method for network elements to synchronize to an accurate time source.

NOTE: Change 'NTP_SERVER_1' to the first NTP server listed for your organization.

Solution

Configure the device to use two separate NTP servers.

See Also

https://iasecontent.disa.mil/stigs/zip/U_Network_L2_Switch_V8R26_STIG.zip

Item Details

Category: AUDIT AND ACCOUNTABILITY

References: 800-53|AU-8, CAT|I, CSCv6|6.1, Rule-ID|SV-41497r1_rule, STIG-ID|NET0812, Vuln-ID|V-23747