CISC-ND-001280 - The Cisco switch must generate audit records showing starting and ending time for administrator access to the system.

Warning! Audit Deprecated

This audit has been deprecated and will be removed in a future update.

View Next Audit Version

Information

Without generating audit records that are specific to the security and mission needs of the organization, it would be difficult to establish, correlate, and investigate the events relating to an incident or identify those responsible for one.

Audit records can be generated from various components within the network device (e.g., module or policy filter).

Solution

Configure the switch to log session start and ending per admin session as shown in the example below:

SW1(config)# logging level authpriv 6

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_Cisco_NX-OS_Switch_Y24M04_STIG.zip

Item Details

References: CAT|II, CCI|CCI-000172, Rule-ID|SV-220510r879876_rule, STIG-ID|CISC-ND-001280, STIG-Legacy|SV-110669, STIG-Legacy|V-101565, Vuln-ID|V-220510

Plugin: Cisco

Control ID: b70bb26c99524e83ccef9d249aaddeedfc0e535c06065cc6880d9faf59507a19