JUNI-ND-001030 - The Juniper router must be configured to record time stamps for log records that can be mapped to Coordinated Universal Time (UTC) or Greenwich Mean Time (GMT).

Warning! Audit Deprecated

This audit has been deprecated and will be removed in a future update.

View Next Audit Version

Information

If time stamps are not consistently applied and there is no common time reference, it is difficult to perform forensic analysis.

Time stamps generated by the application include date and time. Time is commonly expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.

Solution

[edit system]
set time-zone UTC

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_Juniper_Router_Y20M07_STIG.zip

Item Details

Category: AUDIT AND ACCOUNTABILITY

References: 800-53|AU-8, CAT|II, CCI|CCI-001890, Rule-ID|SV-101259r1_rule, STIG-ID|JUNI-ND-001030, Vuln-ID|V-91159

Plugin: Juniper

Control ID: a95ba6f418ba70887eb3014c5dbbd269c3f0004f2ff653b32010c138fdc21355