2.023 - Standard user accounts must only have Read permissions to the Winlogon registry key.

Information

Permissions on the Winlogon registry key must only allow privileged accounts to change registry values. If standard users have this capability there is a potential for programs to run with elevated privileges when a privileged user logs on to the system.

Solution

Maintain the default permissions of the following registry key-

HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Windows NT\CurrentVersion\Winlogon\

Users - Read
Administrators - Full Control
SYSTEM - Full Control
CREATOR OWNER - Special
(Special = Full Control - Subkeys only)

See Also

http://iasecontent.disa.mil/stigs/zip/Oct2016/U_Windows_Vista_V6R41_STIG.zip

Item Details

Category: ACCESS CONTROL

References: 800-53|AC-6(10), CAT|I, CCI|CCI-002235, Rule-ID|SV-33307r2_rule, STIG-ID|2.023, Vuln-ID|V-26070

Plugin: Windows

Control ID: 0bf461ac6d53e7cb531ef0ce5765c64f219e4e6b87f596a4817373a568cb46bb