EX16-ED-000280 - Exchange Receive connectors must be clearly named.

Warning! Audit Deprecated

This audit has been deprecated and will be removed in a future update.

View Next Audit Version

Information

For receive connectors, unclear naming as to direction and purpose increases risk that messages may not flow as intended, troubleshooting efforts may be impaired, or incorrect assumptions may be made about the completeness of the configuration.

Collectively, connectors should account for all connections required for the overall email topology design. Simple Mail Transfer Protocol (SMTP) connectors, when listed, must name purpose and direction clearly, and their counterparts on servers to which they connect should be recognizable as their partners.

NOTE: Nessus has provided the target output to assist in reviewing the benchmark to ensure target compliance.

Solution

Open the Exchange Management Shell and enter the following command:

Set-ReceiveConnector -Name <'NewName'> -Identity <'IdentityName'>

Note: Both the <NewName> and <IdentityName> value must be in single quotes.

Repeat the procedure for each receive connector.

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_MS_Exchange_2016_Y20M10_STIG.zip

Item Details

Category: CONFIGURATION MANAGEMENT

References: 800-53|CM-6, CAT|III, CCI|CCI-001095, Rule-ID|SV-221227r508017_rule, STIG-ID|EX16-ED-000280, STIG-Legacy|SV-95245, STIG-Legacy|V-80535, Vuln-ID|V-221227