EX16-ED-000270 - Exchange Receive connector Maximum Hop Count must be 60.

Warning! Audit Deprecated

This audit has been deprecated and will be removed in a future update.

View Next Audit Version

Information

Email system availability depends in part on best practice strategies for setting tuning configurations. This setting controls the maximum number of hops (email servers traversed) a message may take as it travels to its destination. Part of the original Internet protocol implementation, the hop count limit prevents a message from being passed in a routing loop indefinitely. Messages exceeding the maximum hop count are discarded undelivered.

Recent studies indicate that virtually all messages can be delivered in fewer than 60 hops. If the hop count is set too low, messages may expire before they reach their destinations. If set too high, an undeliverable message may cycle between servers, raising the risk of network congestion.

Solution

Update the EDSP to reflect the value for Receive connectors.

Open the Exchange Management Shell and enter the following command:

Set-ReceiveConnector -Identity <'IdentityName'> -MaxHopCount 60

Note: The <IdentityName> value must be in single quotes.

or

The value as identified by the EDSP that has obtained a signoff with risk acceptance.

Repeat the procedure for each receive connector.