DTOO346 - Project - Untrusted intranet zone access to Project servers must not be allowed.

Information

Enabling this setting allows users to access Project Server websites and workspaces outside of the trusted Internet zone. As a result, malicious code could become active on user computers or the network to gain access to sensitive data. In this situation, the site could attempt to capture personal information, like passwords and user names.

Solution

Set the policy value for User Configuration -> Administrative Templates -> Microsoft Project 2010 -> Project Options -> Security 'Enable untrusted intranet zone access to Project server' to 'Disabled'.

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_MS_Project_2010_V1R10_STIG.zip

Item Details

Category: SYSTEM AND COMMUNICATIONS PROTECTION

References: 800-53|SC-18(4), CAT|II, CCI|CCI-001170, Rule-ID|SV-34091r1_rule, STIG-ID|DTOO346, Vuln-ID|V-26691

Plugin: Windows

Control ID: 7e047a739575437c5dd63d6816c35d9f31a74698de526c7b77e5dd821787696a