OH12-1X-000153 - OHS must have the LoadModule proxy_connect_module directive disabled.

Information

A web server should be primarily a web server or a proxy server but not both, for the same reasons that other multi-use servers are not recommended. Scanning for web servers that will also proxy requests into an otherwise protected network is a very common attack making the attack anonymous.

Solution

1. Open $DOMAIN_HOME/config/fmwconfig/components/OHS/<componentName>/httpd.conf with an editor.

2. Search for the 'LoadModule proxy_connect_module' directive at the OHS server configuration scope.

3. Comment out the 'LoadModule proxy_connnect_module' directive if it exists.

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_Oracle_HTTP_Server_12-1-3_V2R2_STIG.zip

Item Details

Category: CONFIGURATION MANAGEMENT

References: 800-53|CM-7a., CAT|II, CCI|CCI-000381, Rule-ID|SV-221400r879587_rule, STIG-ID|OH12-1X-000153, STIG-Legacy|SV-78865, STIG-Legacy|V-64375, Vuln-ID|V-221400

Plugin: Unix

Control ID: 03cf806443a0df2a77a636cb96b49f3fbd99765a63e7b505a47845026014c76d