OH12-1X-000139 - OHS must have the LoadModule cern_meta_module directive disabled.

Information

A web server can provide many features, services, and processes. Some of these may be deemed unnecessary or too unsecure to run on a production DoD system.

The web server must provide the capability to disable, uninstall, or deactivate functionality and services that are deemed to be non-essential to the web server mission or can adversely impact server performance.

Solution

1. Open $DOMAIN_HOME/config/fmwconfig/components/OHS/<componentName>/httpd.conf with an editor.

2. Search for the 'LoadModule cern_meta_module' directive at the OHS server configuration scope.

3. Comment out the 'LoadModule cern_meta_module' directive if it exists.

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_Oracle_HTTP_Server_12-1-3_V2R2_STIG.zip

Item Details

Category: CONFIGURATION MANAGEMENT

References: 800-53|CM-7a., CAT|III, CCI|CCI-000381, Rule-ID|SV-221386r879587_rule, STIG-ID|OH12-1X-000139, STIG-Legacy|SV-78825, STIG-Legacy|V-64335, Vuln-ID|V-221386

Plugin: Unix

Control ID: 053d80e90dfeca5d944a4df8d516c4f9a3860edb87bc89bd6a082efea2bff4ad