OH12-1X-000040 - OHS must have the client requests logging module loaded to generate log records for system startup and shutdown, system access, and system authentication logging.

Information

Log records can be generated from various components within the web server (e.g., httpd, plug-ins to external backends, etc.). From a web server perspective, certain specific web server functionalities may be logged as well. The web server must allow the definition of what events are to be logged. As conditions change, the number and types of events to be logged may change, and the web server must be able to facilitate these changes.

The minimum list of logged events should be those pertaining to system startup and shutdown, system access, and system authentication events. If these events are not logged at a minimum, any type of forensic investigation would be missing pertinent information needed to replay what occurred.

Solution

1. Open $DOMAIN_HOME/config/fmwconfig/components/OHS/<componentName>/httpd.conf with an editor.

2. Search for the 'LoadModule log_config_module' directive at the OHS server configuration scope.

3. Set the 'LoadModule log_config_module' directive to ''${PRODUCT_HOME}/modules/mod_log_config.so'', add the directive if it does not exist.

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_Oracle_HTTP_Server_12-1-3_V2R2_STIG.zip

Item Details

Category: AUDIT AND ACCOUNTABILITY

References: 800-53|AU-12a., CAT|II, CCI|CCI-000169, Rule-ID|SV-221303r879559_rule, STIG-ID|OH12-1X-000040, STIG-Legacy|SV-78663, STIG-Legacy|V-64173, Vuln-ID|V-221303

Plugin: Unix

Control ID: f0cd49b57e744c1a5ab9e71736fcf492e127983fb843ab4623277aa5bd28ef07