3.063-MS - Named pipes that can be accessed anonymously will be configured to contain no values.

Information

This is a Category 1 finding due to the potential for gaining unauthorized system access. Pipes are internal system communications processes. They are identified internally by ID numbers that vary between systems. To make access to these processes easier, these pipes are given names that do not vary between systems. This setting controls which of these pipes may be accessed anonymously.

Solution

Configure the policy value for Computer Configuration -> Windows Settings -> Security Settings -> Local Policies -> Security Options -> 'Network access: Named pipes that can be accessed anonymously' to include no entries (blank).

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_MS_Windows_2008_R2_MS_V1R33_STIG.zip

Item Details

Category: IDENTIFICATION AND AUTHENTICATION

References: 800-53|IA-2(2), CAT|I, CCI|CCI-001090, CSCv6|14.1, Rule-ID|SV-32481r2_rule, STIG-ID|3.063-MS, Vuln-ID|V-3338

Plugin: Windows

Control ID: 4182ea4647ed69a8395586e8a6a2395adf2a8609dc026d85bce43e741e61bc8f