WN12-CC-000055 - The user must be prompted to authenticate on resume from sleep (plugged in).

Information

Authentication must always be required when accessing a system. This setting ensures the user is prompted for a password on resume from sleep (plugged in).

Solution

Configure the policy value for Computer Configuration -> Administrative Templates -> System -> Power Management -> Sleep Settings -> 'Require a password when a computer wakes (plugged in)' to 'Enabled'.

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_MS_Windows_2012_and_2012_R2_MS_V3R7_STIG.zip

Item Details

Category: IDENTIFICATION AND AUTHENTICATION

References: 800-53|IA-11, CAT|II, CCI|CCI-002038, Rule-ID|SV-225352r852207_rule, STIG-ID|WN12-CC-000055, STIG-Legacy|SV-53132, STIG-Legacy|V-15706, Vuln-ID|V-225352

Plugin: Windows

Control ID: 155b2f10987153dd387dc60ab094a318fc61e57ba5d018ff86d33e8270261d0e