WN12-AU-000060 - The system must be configured to audit Object Access - Central Access Policy Staging failures.

Information

Maintaining an audit trail of system activity logs can help identify configuration errors, troubleshoot service disruptions, and analyze compromises that have occurred, as well as detect attacks. Audit logs are necessary to provide a trail of evidence in case the system or network is compromised. Collecting this data is essential for analyzing the security of information assets and detecting signs of suspicious and unexpected behavior.

Central Access Policy Staging auditing under Object Access is used to enable the recording of events related to differences in permissions between central access policies and proposed policies.

Solution

Configure the policy value for Computer Configuration -> Windows Settings -> Security Settings -> Advanced Audit Policy Configuration -> System Audit Policies -> Object Access -> 'Audit Central Access Policy Staging' with 'Failure' selected.

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_MS_Windows_2012_and_2012_R2_MS_V3R7_STIG.zip

Item Details

Category: AUDIT AND ACCOUNTABILITY

References: 800-53|AU-12c., CAT|II, CCI|CCI-000172, Rule-ID|SV-225289r569185_rule, STIG-ID|WN12-AU-000060, STIG-Legacy|SV-52159, STIG-Legacy|V-40200, Vuln-ID|V-225289

Plugin: Windows

Control ID: 7a7cb785caefee62c4ba32648a882d2b9e29a0ef4aa72eff10d26ad0e89eb34a