SHPT-00-000645 - SharePoint must terminate the network connection after a defined time period - 'FormDigestSettings.Enabled = True'

Warning! Audit Deprecated

This audit has been deprecated and will be removed in a future update.

View Next Audit Version

Information

SHPT-00-000645 - SharePoint must terminate the network connection associated with a communications session at the end of the session or after an organizationally defined time period of inactivity - 'FormDigestSettings.Enabled = True'
This requirement applies to both internal and external networks. Terminating network connections associated with communications sessions include, de-allocating associated TCP/IP address/port pairs at the operating-system level, or de-allocating networking assignments at the application level if multiple application sessions are using a single operating system-level network connection.

The time period of inactivity may, as the organization deems necessary, be a set of time periods by type of network access or for specific accesses.

Solution

1. In SharePoint Central Administration, click Application Management.
2. On the Application Management page, in the Web Applications list, click Manage web applications.
3. Click a web application, and then click General Settings in the Manage section of the ribbon.
4. In the Web Application General Settings dialog window, in the Web Page Security Validation section, set Web Page Security Validation to On and a value less than 10 minutes.

See Also

http://iasecontent.disa.mil/stigs/zip/Oct2015/U_Sharepoint_2010_V1R7_STIG.zip

Item Details

Category: ACCESS CONTROL

References: 800-53|AC-12, CAT|II, CCI|CCI-001133, Rule-ID|SV-37794r2_rule, STIG-ID|SHPT-00-000645, Vuln-ID|V-28071

Plugin: Windows