SOL-11.1-020100 - The legacy remote network access utilities daemons must not be installed.

Information

Legacy remote access utilities allow remote control of a system without proper authentication.

Solution

The Software Installation Profile is required.

# pfexec pkg uninstall service/network/legacy-remote-utilities

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_SOL_11_x86_V3R1_STIG.zip

Item Details

Category: CONFIGURATION MANAGEMENT

References: 800-53|CM-6b., CAT|II, CCI|CCI-000366, Rule-ID|SV-216052r959010_rule, STIG-ID|SOL-11.1-020100, STIG-Legacy|SV-60773, STIG-Legacy|V-47901, Vuln-ID|V-216052

Plugin: Unix

Control ID: 187e5aa55c1bad2697b53c4865a1d16a6b23c8896b069f4bab43ae2e26807f8f