SYMP-AG-000580 - Symantec ProxySG must identify and log internal users associated with denied outgoing communications traffic posing a threat to external information systems - Access Logging Enabled

Information

Without identifying the users who initiated the traffic, it would be difficult to identify those responsible for the denied communications.

This requirement applies to network elements that perform Data Leakage Prevention (DLP) (e.g., ALGs, proxies, or application level firewalls).

Solution

Configure the ProxySG to log user web traffic for auditing.

1. Log on to the Web Management Console.
2. Browse to 'Configuration' and click 'Access Logging'. Check the 'Enable Access Logging' option and click 'Apply'.
3. Click Policy >> Visual Policy Manager >> Launch.
4. For each Web Access Layer, right-click the 'Track' column for each rule that has 'Action' set to 'Deny' and 'Destination' defined as a restricted set of potentially threatening destinations and select 'Set'.
5. Click 'New' and select 'Event Log'.

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_SYM_ProxySG_Y20M04_STIG.zip

Item Details

Category: SYSTEM AND COMMUNICATIONS PROTECTION

References: 800-53|SC-7(9)(b), CAT|II, CCI|CCI-002400, Rule-ID|SV-104283r1_rule, STIG-ID|SYMP-AG-000580, Vuln-ID|V-94329