ZEBR-11-010200 - Zebra Android 11 must be configured to disallow configuration of date and time.

Information

Determining the correct time a particular application event occurred on a system is critical when conducting forensic analysis and investigating system events.

Periodically synchronizing internal clocks with an authoritative time source is necessary to correctly correlate the timing of events that occur across the enterprise. The three authoritative time sources for Zebra Android 11 are an authoritative time server that is synchronized with redundant United States Naval Observatory (USNO) time servers as designated for the appropriate DoD network (NIPRNet or SIPRNet), the Global Positioning System (GPS), or the wireless carrier.

Time stamps generated by the audit system in Zebra Android 11 must include both date and time. The time may be expressed in Coordinated Universal Time (UTC), a modern continuation of Greenwich Mean Time (GMT), or local time with an offset from UTC.

SFR ID: FMT_SMF_EXT.1.1 #47

Solution

Configure Zebra Android 11 work Profile to set auto network time.

On the EMM console:
1. Open 'Set user restrictions on parent'.
2. Toggle 'Disallow config date time' to 'On'.

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_Zebra_Android_11_COBO_V1R3_STIG.zip

Item Details

Category: CONFIGURATION MANAGEMENT

References: 800-53|CM-6b., CAT|II, CCI|CCI-000366, Rule-ID|SV-252877r820558_rule, STIG-ID|ZEBR-11-010200, Vuln-ID|V-252877

Plugin: MDM

Control ID: 80290faa0f8ad410b16af4b1c3b6a42e8936e3d866e28c7eacf85237f34674d2