VCST-80-000057 The vCenter STS service must be configured to limit data exposure between applications.

Information

If RECYCLE_FACADES is true or if a security manager is in use, a new facade object will be created for each request. This reduces the chances that a bug in an application might expose data from one request to another.

Solution

Navigate to and open:

/usr/lib/vmware-sso/vmware-sts/conf/catalina.properties

Update or remove the following line:

org.apache.catalina.connector.RECYCLE_FACADES=true

Restart the service with the following command:

# vmon-cli --restart sts

See Also

https://dl.dod.cyber.mil/wp-content/uploads/stigs/zip/U_VMW_vSphere_8-0_Y24M08_STIG.zip

Item Details

Category: SYSTEM AND COMMUNICATIONS PROTECTION

References: 800-53|SC-23(3), CAT|II, CCI|CCI-001664, Rule-ID|SV-258979r961116_rule, STIG-ID|VCST-80-000057, Vuln-ID|V-258979

Plugin: Unix