Ensure 'logging to Serial console' is disabled

Information

Disables the logging to the Serial console

Rationale:

Enabling the logs to be sent to the Serial console may negatively impact the logging to the buffer and remote syslog servers and to a certain extent the buffer and syslog servers may no longer receive logs because the logs generation will follow the Serial console speed.

Solution

Firepower Device Manager:

Use Objects > Syslog Servers and Device > System Settings > Logging Settings.

or

Firepower Management Center:

Device > Platform Setting > Threat Defense Policy > Syslog > Syslog Settings

See Also

https://www.cisco.com/c/en/us/td/docs/security/firepower/623/configuration/guide/fpmc-config-guide-v623.html

Item Details

Category: AUDIT AND ACCOUNTABILITY

References: 800-53|AU-12c.

Plugin: Cisco

Control ID: 268c02ddc6d8ddf5376462e08a1648221ae86e783dfc8298ef45931b53d6e816