On Juniper Networks EX Series Ethernet Switches running affected Junos OS versions, a vulnerability in IPv6 processing has been discovered that may allow a specially crafted IPv6 Neighbor Discovery (ND) packet destined to an EX Series Ethernet Switch to cause a slow memory leak. A malicious network-based packet flood of these crafted IPv6 NDP packets may eventually lead to resource exhaustion and a denial of service. The affected Junos OS versions are: 12.3 prior to 12.3R12-S4, 12.3R13; 13.3 prior to 13.3R10; 14.1 prior to 14.1R8-S3, 14.1R9; 14.1X53 prior ro 14.1X53-D12, 14.1X53-D40; 14.1X55 prior to 14.1X55-D35; 14.2 prior to 14.2R6-S4, 14.2R7-S6, 14.2R8; 15.1 prior to 15.1R5; 16.1 before 16.1R3; 16.2 before 16.2R1-S3, 16.2R2. 17.1R1 and all subsequent releases have a resolution for this vulnerability.

References

https://kb.juniper.net/JSA10781

http://www.securitytracker.com/id/1038253

http://www.securityfocus.com/bid/97615

Details

Source: Mitre, NVD

Published: 2017-04-24

Updated: 2019-10-03

Risk Information

CVSS v2

Base Score: 7.8

Vector: CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:C

Severity: High

CVSS v3

Base Score: 7.5

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Severity: High