CVE-2017-6015

high

Description

Without quotation marks, any whitespace in the file path for Rockwell Automation FactoryTalk Activation version 4.00.02 remains ambiguous, which may allow an attacker to link to or run a malicious executable. This may allow an authorized, but not privileged local user to execute arbitrary code with elevated privileges on the system. CVSS v3 base score: 8.8, CVSS vector string: (AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H). Rockwell Automation has released a new version of FactoryTalk Activation, Version 4.01, which addresses the identified vulnerability. Rockwell Automation recommends upgrading to the latest version of FactoryTalk Activation, Version 4.01 or later.

References

https://rockwellautomation.custhelp.com/app/answers/detail/a_id/939382

https://ics-cert.us-cert.gov/advisories/ICSA-17-047-02

http://www.securityfocus.com/bid/96996

Details

Source: Mitre, NVD

Published: 2018-05-11

Updated: 2024-11-21

Risk Information

CVSS v2

Base Score: 7.2

Vector: CVSS2#AV:L/AC:L/Au:N/C:C/I:C/A:C

Severity: High

CVSS v3

Base Score: 7.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Severity: High