CVE-2018-4859

high

Description

A vulnerability has been identified in SCALANCE M875 (All versions). An authenticated remote attacker with access to the web interface (443/tcp), could execute arbitrary operating system commands. Successful exploitation requires that the attacker has network access to the web interface. The attacker must be authenticated as administrative user to exploit the security vulnerability. The vulnerability could allow an attacker to execute arbitrary code on the device. At the time of advisory publication no public exploitation of this security vulnerability was known.

References

https://cert-portal.siemens.com/productcert/pdf/ssa-977428.pdf

Details

Source: Mitre, NVD

Published: 2018-06-26

Updated: 2019-10-09

Risk Information

CVSS v2

Base Score: 9

Vector: CVSS2#AV:N/AC:L/Au:S/C:C/I:C/A:C

Severity: High

CVSS v3

Base Score: 7.2

Vector: CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H

Severity: High