CVE-2021-20107

medium

Description

There exists an unauthenticated BLE Interface in Sloan SmartFaucets including Optima EAF, Optima ETF/EBF, BASYS EFX, and Flushometers including SOLIS. The vulnerability allows for unauthenticated kinetic effects and information disclosure on the faucets. It is possible to use the Bluetooth Low Energy (BLE) connectivity to read and write to many BLE characteristics on the device. Some of these control the flow of water, the sensitivity of the sensors, and information about maintenance.

References

https://www.tenable.com/security/research/tra-2021-26-0

Details

Source: Mitre, NVD

Published: 2021-06-30

Updated: 2022-06-28

Risk Information

CVSS v2

Base Score: 4.8

Vector: CVSS2#AV:A/AC:L/Au:N/C:P/I:P/A:N

Severity: Medium

CVSS v3

Base Score: 5.4

Vector: CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N

Severity: Medium