CVE-2021-25667

high

Description

A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active.

References

https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03

https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf

Details

Source: Mitre, NVD

Published: 2021-03-15

Updated: 2024-11-21

Risk Information

CVSS v2

Base Score: 5.8

Vector: CVSS2#AV:A/AC:L/Au:N/C:P/I:P/A:P

Severity: Medium

CVSS v3

Base Score: 8.8

Vector: CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Severity: High