CVE-2021-41769

high

Description

A vulnerability has been identified in SIPROTEC 5 6MD85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MD89 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 6MU85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7KE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SA86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SA87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SD86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SD87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ81 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SJ85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SJ86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SK82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SK85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7SL86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SL87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SS85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7ST85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7SX85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UM85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT82 devices (CPU variant CP100) (All versions < V8.83), SIPROTEC 5 7UT85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT86 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7UT87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VE85 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 7VK87 devices (CPU variant CP300) (All versions < V8.83), SIPROTEC 5 Compact 7SX800 devices (CPU variant CP050) (All versions < V8.83). An improper input validation vulnerability in the web server could allow an unauthenticated user to access device information.

References

https://cert-portal.siemens.com/productcert/pdf/ssa-439673.pdf

Details

Source: Mitre, NVD

Published: 2022-01-11

Updated: 2022-01-19

Risk Information

CVSS v2

Base Score: 5

Vector: CVSS2#AV:N/AC:L/Au:N/C:P/I:N/A:N

Severity: Medium

CVSS v3

Base Score: 7.5

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N

Severity: High