CVE-2024-12371

critical

Description

A device takeover vulnerability exists in the Rockwell Automation Power Monitor 1000. This vulnerability allows configuration of a new Policyholder user without any authentication via API. Policyholder user is the most privileged user that can perform edit operations, creating admin users and performing factory reset.

References

https://www.securityweek.com/rockwell-powermonitor-vulnerabilities-allow-remote-hacking-of-industrial-systems/

https://www.cisa.gov/news-events/ics-advisories/icsa-24-352-03

https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1714.html

Details

Source: Mitre, NVD

Published: 2024-12-18

Updated: 2024-12-18

Risk Information

CVSS v2

Base Score: 6.5

Vector: CVSS2#AV:N/AC:L/Au:S/C:P/I:P/A:P

Severity: Medium

CVSS v3

Base Score: 8.8

Vector: CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Severity: High

CVSS v4

Base Score: 9.3

Vector: CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N

Severity: Critical