CVE-2024-2487

high

Description

A vulnerability was found in Tenda AC18 15.03.05.05. It has been declared as critical. This vulnerability affects the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName/mac leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-256894 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

References

https://vuldb.com/?id.256894

https://vuldb.com/?ctiid.256894

https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC18/formSetDeviceName_devName.md

Details

Source: Mitre, NVD

Published: 2024-03-15

Updated: 2024-05-17

Risk Information

CVSS v2

Base Score: 9

Vector: CVSS2#AV:N/AC:L/Au:S/C:C/I:C/A:C

Severity: High

CVSS v3

Base Score: 8.8

Vector: CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Severity: High