EMC VMAX VASA Provider Virtual Appliance < 8.4.0 File Upload RCE

critical Nessus Plugin ID 102036

Synopsis

The remote virtual appliance is affected by a remote code execution vulnerability.

Description

The version of EMC VMAX VASA Provider Virtual Appliance running on the remote host is prior to 8.4.0. It is, therefore, affected by a remote code execution vulnerability in the UploadConfigurator servlet due to a failure to restrict file uploads to arbitrary directories. An unauthenticated, remote attacker can exploit this issue to upload files containing arbitrary code and then execute them with root privileges.

Solution

Upgrade to EMC VMAX VASA Provider Virtual Appliance version 8.4.0 or later.

See Also

https://seclists.org/bugtraq/2017/Jun/att-55/ESA-2017-062.txt

https://www.zerodayinitiative.com/advisories/ZDI-17-491/

Plugin Details

Severity: Critical

ID: 102036

File Name: emc_vapp_manager_vasa_provider_ESA_2017_062.nasl

Version: 1.7

Type: remote

Family: CGI abuses

Published: 7/28/2017

Updated: 6/12/2020

Supported Sensors: Nessus

Risk Information

VPR

Risk Factor: Medium

Score: 5.9

CVSS v2

Risk Factor: Critical

Base Score: 10

Temporal Score: 8.3

Vector: CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C

CVSS v3

Risk Factor: Critical

Base Score: 9.8

Temporal Score: 9.1

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:F/RL:O/RC:X

Vulnerability Information

CPE: x-cpe:/a:emc:vasa_provider_virtual_appliance

Required KB Items: Host/EMC/VMAX VASA Provider Virtual Appliance

Exploit Available: true

Exploit Ease: Exploits are available

Patch Publication Date: 6/28/2017

Vulnerability Publication Date: 6/28/2017

Reference Information

CVE: CVE-2017-4997

BID: 99169