ESXi 6.0 / 6.5 / 6.7 Multiple Vulnerabilities (VMSA-2019-0005) (Remote Check)

medium Nessus Plugin ID 123518

Synopsis

The remote VMware ESXi host is missing a security patch and is affected by multiple vulnerabilities.

Description

The remote VMware ESXi host is version 6.0, 6.5, or 6.7 and is missing a security patch. It is, therefore, vulnerable to multiple vulnerabilities, including:

- An out-of-bounds read/write vulnerability and a Time-of-check Time-of-use (TOCTOU) vulnerability in the virtual USB 1.1 UHCI (Universal Host Controller Interface). Exploitation of these issues requires an attacker to have access to a virtual machine with a virtual USB controller present. These issues may allow a guest to execute code on the host. (CVE-2019-5518, CVE-2019-5519)

Solution

Apply the appropriate patch as referenced in the vendor advisory.

See Also

https://www.vmware.com/security/advisories/VMSA-2019-0005.html

Plugin Details

Severity: Medium

ID: 123518

File Name: vmware_esxi_VMSA-2019-0005.nasl

Version: 1.5

Type: remote

Family: Misc.

Published: 3/29/2019

Updated: 12/5/2022

Supported Sensors: Nessus

Risk Information

VPR

Risk Factor: Medium

Score: 5.9

CVSS v2

Risk Factor: High

Base Score: 7.2

Temporal Score: 5.3

Vector: CVSS2#AV:L/AC:L/Au:N/C:C/I:C/A:C

CVSS Score Source: CVE-2019-5519

CVSS v3

Risk Factor: Medium

Base Score: 6.8

Temporal Score: 5.9

Vector: CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:vmware:esxi

Required KB Items: Host/VMware/version, Host/VMware/release, Host/VMware/vsphere

Exploit Ease: No known exploits are available

Patch Publication Date: 3/28/2019

Vulnerability Publication Date: 3/28/2019

Reference Information

CVE: CVE-2019-5518, CVE-2019-5519

IAVA: 2019-A-0099

VMSA: 2019-0005