Tenda AC Router Command Injection (CVE-2018-14558)

critical Nessus Plugin ID 186331

Synopsis

The remote router is affected by a command injection vulnerability.

Description

The firmware version of the Tenda AC Router is an AC7 device with firmware V15.03.06.44_CN(AC7) or below, an AC9 device with firmware V15.03.05.19(6318)_CN(AC9) or below, or an AC10 devices with firmware V15.03.06.23_CN(AC10) or below. It is, therefore, affected by a command injection vulnerability. An unauthenticated, remote attacker can exploit this, via a crafted goform/setUsbUnload request, to execute arbitrary OS commands.

Note that Nessus has not tested for this issue but has instead relied only on the application's self-reported version number.

Solution

Update to a newer version of device firmware.

See Also

https://nvd.nist.gov/vuln/detail/CVE-2018-14558

Plugin Details

Severity: Critical

ID: 186331

File Name: tenda_ac_router_cve-2018-14558.nasl

Version: 1.1

Type: remote

Family: CGI abuses

Published: 11/28/2023

Updated: 11/28/2023

Supported Sensors: Nessus

Risk Information

VPR

Risk Factor: High

Score: 7.4

CVSS v2

Risk Factor: Critical

Base Score: 10

Temporal Score: 8.3

Vector: CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C

CVSS Score Source: CVE-2018-14558

CVSS v3

Risk Factor: Critical

Base Score: 9.8

Temporal Score: 9.1

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:F/RL:O/RC:C

Vulnerability Information

CPE: cpe:/h:tenda:ac7, cpe:/h:tenda:ac9, cpe:/h:tenda:ac10

Required KB Items: installed_sw/Tenda AC Router

Exploit Available: true

Exploit Ease: Exploits are available

Patch Publication Date: 10/30/2018

Vulnerability Publication Date: 10/30/2018

CISA Known Exploited Vulnerability Due Dates: 5/3/2022

Reference Information

CVE: CVE-2018-14558