EulerOS 2.0 SP9 : docker-engine (EulerOS-SA-2024-1955)

high Nessus Plugin ID 202530

Synopsis

The remote EulerOS host is missing multiple security updates.

Description

According to the versions of the docker-engine packages installed, the EulerOS installation on the remote host is affected by the following vulnerabilities :

Moby is an open source container framework developed by Docker Inc. that is distributed as Docker, Mirantis Container Runtime, and various other downstream projects/products. The Moby daemon component (`dockerd`), which is developed as moby/moby, is commonly referred to as *Docker*. Swarm Mode, which is compiled in and delivered by default in dockerd and is thus present in most major Moby downstreams, is a simple, built-in container orchestrator that is implemented through a combination of SwarmKit and supporting network code. The overlay network driver is a core feature of Swarm Mode, providing isolated virtual LANs that allow communication between containers and services across the cluster. This driver is an implementation/user of VXLAN, which encapsulates link-layer (Ethernet) frames in UDP datagrams that tag the frame with a VXLAN Network ID (VNI) that identifies the originating overlay network. In addition, the overlay network driver supports an optional, off-by-default encrypted mode, which is especially useful when VXLAN packets traverses an untrusted network between nodes. Encrypted overlay networks function by encapsulating the VXLAN datagrams through the use of the IPsec Encapsulating Security Payload protocol in Transport mode. By deploying IPSec encapsulation, encrypted overlay networks gain the additional properties of source authentication through cryptographic proof, data integrity through check-summing, and confidentiality through encryption. When setting an endpoint up on an encrypted overlay network, Moby installs three iptables (Linux kernel firewall) rules that enforce both incoming and outgoing IPSec. These rules rely on the u32 iptables extension provided by the xt_u32 kernel module to directly filter on a VXLAN packet's VNI field, so that IPSec guarantees can be enforced on encrypted overlay networks without interfering with other overlay networks or other users of VXLAN. Two iptables rules serve to filter incoming VXLAN datagrams with a VNI that corresponds to an encrypted network and discards unencrypted datagrams. The rules are appended to the end of the INPUT filter chain, following any rules that have been previously set by the system administrator. Administrator-set rules take precedence over the rules Moby sets to discard unencrypted VXLAN datagrams, which can potentially admit unencrypted datagrams that should have been discarded. The injection of arbitrary Ethernet frames can enable a Denial of Service attack. A sophisticated attacker may be able to establish a UDP or TCP connection by way of the containers outbound gateway that would otherwise be blocked by a stateful firewall, or carry out other escalations beyond simple injection by smuggling packets into the overlay network. Patches are available in Moby releases 23.0.3 and 20.10.24. As Mirantis Container Runtime's 20.10 releases are numbered differently, users of that platform should update to 20.10.16. Some workarounds are available. Close the VXLAN port (by default, UDP port 4789) to incoming traffic at the Internet boundary to prevent all VXLAN packet injection, and/or ensure that the `xt_u32` kernel module is available on all nodes of the Swarm cluster.(CVE-2023-28840)

Moby is an open source container framework developed by Docker Inc. that is distributed as Docker, Mirantis Container Runtime, and various other downstream projects/products. The Moby daemon component (`dockerd`), which is developed as moby/moby is commonly referred to as *Docker*. Swarm Mode, which is compiled in and delivered by default in `dockerd` and is thus present in most major Moby downstreams, is a simple, built-in container orchestrator that is implemented through a combination of SwarmKit and supporting network code. The `overlay` network driver is a core feature of Swarm Mode, providing isolated virtual LANs that allow communication between containers and services across the cluster. This driver is an implementation/user of VXLAN, which encapsulates link-layer (Ethernet) frames in UDP datagrams that tag the frame with the VXLAN metadata, including a VXLAN Network ID (VNI) that identifies the originating overlay network. In addition, the overlay network driver supports an optional, off-by-default encrypted mode, which is especially useful when VXLAN packets traverses an untrusted network between nodes.
Encrypted overlay networks function by encapsulating the VXLAN datagrams through the use of the IPsec Encapsulating Security Payload protocol in Transport mode. By deploying IPSec encapsulation, encrypted overlay networks gain the additional properties of source authentication through cryptographic proof, data integrity through check-summing, and confidentiality through encryption. When setting an endpoint up on an encrypted overlay network, Moby installs three iptables (Linux kernel firewall) rules that enforce both incoming and outgoing IPSec. These rules rely on the `u32` iptables extension provided by the `xt_u32` kernel module to directly filter on a VXLAN packet's VNI field, so that IPSec guarantees can be enforced on encrypted overlay networks without interfering with other overlay networks or other users of VXLAN. An iptables rule designates outgoing VXLAN datagrams with a VNI that corresponds to an encrypted overlay network for IPsec encapsulation. Encrypted overlay networks on affected platforms silently transmit unencrypted data. As a result, `overlay` networks may appear to be functional, passing traffic as expected, but without any of the expected confidentiality or data integrity guarantees. It is possible for an attacker sitting in a trusted position on the network to read all of the application traffic that is moving across the overlay network, resulting in unexpected secrets or user data disclosure. Thus, because many database protocols, internal APIs, etc. are not protected by a second layer of encryption, a user may use Swarm encrypted overlay networks to provide confidentiality, which due to this vulnerability this is no longer guaranteed. Patches are available in Moby releases 23.0.3, and 20.10.24. As Mirantis Container Runtime's 20.10 releases are numbered differently, users of that platform should update to 20.10.16. Some workarounds are available. Close the VXLAN port (by default, UDP port 4789) to outgoing traffic at the Internet boundary in order to prevent unintentionally leaking unencrypted traffic over the Internet, and/or ensure that the `xt_u32` kernel module is available on all nodes of the Swarm cluster.(CVE-2023-28841)

Moby is an open source container framework developed by Docker Inc. that is distributed as Docker, Mirantis Container Runtime, and various other downstream projects/products. The Moby daemon component (`dockerd`), which is developed as moby/moby is commonly referred to as *Docker*. Swarm Mode, which is compiled in and delivered by default in `dockerd` and is thus present in most major Moby downstreams, is a simple, built-in container orchestrator that is implemented through a combination of SwarmKit and supporting network code. The `overlay` network driver is a core feature of Swarm Mode, providing isolated virtual LANs that allow communication between containers and services across the cluster. This driver is an implementation/user of VXLAN, which encapsulates link-layer (Ethernet) frames in UDP datagrams that tag the frame with the VXLAN metadata, including a VXLAN Network ID (VNI) that identifies the originating overlay network. In addition, the overlay network driver supports an optional, off-by-default encrypted mode, which is especially useful when VXLAN packets traverses an untrusted network between nodes.
Encrypted overlay networks function by encapsulating the VXLAN datagrams through the use of the IPsec Encapsulating Security Payload protocol in Transport mode. By deploying IPSec encapsulation, encrypted overlay networks gain the additional properties of source authentication through cryptographic proof, data integrity through check-summing, and confidentiality through encryption. When setting an endpoint up on an encrypted overlay network, Moby installs three iptables (Linux kernel firewall) rules that enforce both incoming and outgoing IPSec. These rules rely on the `u32` iptables extension provided by the `xt_u32` kernel module to directly filter on a VXLAN packet's VNI field, so that IPSec guarantees can be enforced on encrypted overlay networks without interfering with other overlay networks or other users of VXLAN. The `overlay` driver dynamically and lazily defines the kernel configuration for the VXLAN network on each node as containers are attached and detached. Routes and encryption parameters are only defined for destination nodes that participate in the network. The iptables rules that prevent encrypted overlay networks from accepting unencrypted packets are not created until a peer is available with which to communicate. Encrypted overlay networks silently accept cleartext VXLAN datagrams that are tagged with the VNI of an encrypted overlay network. As a result, it is possible to inject arbitrary Ethernet frames into the encrypted overlay network by encapsulating them in VXLAN datagrams. The implications of this can be quite dire, and GHSA-vwm3-crmr-xfxw should be referenced for a deeper exploration. Patches are available in Moby releases 23.0.3, and 20.10.24. As Mirantis Container Runtime's 20.10 releases are numbered differently, users of that platform should update to 20.10.16. Some workarounds are available. In multi- node clusters, deploy a global pause container for each encrypted overlay network, on every node.
For a single-node cluster, do not use overlay networks of any sort. Bridge networks provide the same connectivity on a single node and have no multi-node features. The Swarm ingress feature is implemented using an overlay network, but can be disabled by publishing ports in `host` mode instead of `ingress` mode (allowing the use of an external load balancer), and removing the `ingress` network. If encrypted overlay networks are in exclusive use, block UDP port 4789 from traffic that has not been validated by IPSec.(CVE-2023-28842)

Moby is an open-source project created by Docker to enable software containerization. The classic builder cache system is prone to cache poisoning if the image is built FROM scratch. Also, changes to some instructions (most important being HEALTHCHECK and ONBUILD) would not cause a cache miss. An attacker with the knowledge of the Dockerfile someone is using could poison their cache by making them pull a specially crafted image that would be considered as a valid cache candidate for some build steps. 23.0+ users are only affected if they explicitly opted out of Buildkit (DOCKER_BUILDKIT=0 environment variable) or are using the /build API endpoint. All users on versions older than 23.0 could be impacted. Image build API endpoint (/build) and ImageBuild function from github.com/docker/docker/client is also affected as it the uses classic builder by default. Patches are included in 24.0.9 and 25.0.2 releases.(CVE-2024-24557)

Moby is an open source container framework that is a key component of Docker Engine, Docker Desktop, and other distributions of container tooling or runtimes. Moby's networking implementation allows for many networks, each with their own IP address range and gateway, to be defined. This feature is frequently referred to as custom networks, as each network can have a different driver, set of parameters and thus behaviors. When creating a network, the `--internal` flag is used to designate a network as _internal_.
The `internal` attribute in a docker-compose.yml file may also be used to mark a network _internal_, and other API clients may specify the `internal` parameter as well. When containers with networking are created, they are assigned unique network interfaces and IP addresses. The host serves as a router for non-internal networks, with a gateway IP that provides SNAT/DNAT to/from container IPs. Containers on an internal network may communicate between each other, but are precluded from communicating with any networks the host has access to (LAN or WAN) as no default route is configured, and firewall rules are set up to drop all outgoing traffic. Communication with the gateway IP address (and thus appropriately configured host services) is possible, and the host may communicate with any container IP directly. In addition to configuring the Linux kernel's various networking features to enable container networking, `dockerd` directly provides some services to container networks. Principal among these is serving as a resolver, enabling service discovery, and resolution of names from an upstream resolver. When a DNS request for a name that does not correspond to a container is received, the request is forwarded to the configured upstream resolver. This request is made from the container's network namespace: the level of access and routing of traffic is the same as if the request was made by the container itself. As a consequence of this design, containers solely attached to an internal network will be unable to resolve names using the upstream resolver, as the container itself is unable to communicate with that nameserver.
Only the names of containers also attached to the internal network are able to be resolved. Many systems run a local forwarding DNS resolver. As the host and any containers have separate loopback devices, a consequence of the design described above is that containers are unable to resolve names from the host's configured resolver, as they cannot reach these addresses on the host loopback device. To bridge this gap, and to allow containers to properly resolve names even when a local forwarding resolver is used on a loopback address, `dockerd` detects this scenario and instead forward DNS requests from the host namework namespace. The loopback resolver then forwards the requests to its configured upstream resolvers, as expected. Because `dockerd` forwards DNS requests to the host loopback device, bypassing the container network namespace's normal routing semantics entirely, internal networks can unexpectedly forward DNS requests to an external nameserver. By registering a domain for which they control the authoritative nameservers, an attacker could arrange for a compromised container to exfiltrate data by encoding it in DNS queries that will eventually be answered by their nameservers. Docker Desktop is not affected, as Docker Desktop always runs an internal resolver on a RFC 1918 address. Moby releases 26.0.0, 25.0.4, and 23.0.11 are patched to prevent forwarding any DNS requests from internal networks. As a workaround, run containers intended to be solely attached to internal networks with a custom upstream address, which will force all upstream DNS queries to be resolved from the container's network namespace.(CVE-2024-29018)

Tenable has extracted the preceding description block directly from the EulerOS docker-engine security advisory.

Note that Nessus has not tested for these issues but has instead relied only on the application's self-reported version number.

Solution

Update the affected docker-engine packages.

See Also

http://www.nessus.org/u?2ec8c511

Plugin Details

Severity: High

ID: 202530

File Name: EulerOS_SA-2024-1955.nasl

Version: 1.1

Type: local

Published: 7/16/2024

Updated: 7/16/2024

Supported Sensors: Nessus

Risk Information

VPR

Risk Factor: High

Score: 7.1

CVSS v2

Risk Factor: High

Base Score: 7.2

Temporal Score: 5.6

Vector: CVSS2#AV:L/AC:L/Au:N/C:C/I:C/A:C

CVSS Score Source: CVE-2024-24557

CVSS v3

Risk Factor: High

Base Score: 8.7

Temporal Score: 7.8

Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:H

Temporal Vector: CVSS:3.0/E:P/RL:O/RC:C

CVSS Score Source: CVE-2023-28840

Vulnerability Information

CPE: p-cpe:/a:huawei:euleros:docker-engine-selinux, cpe:/o:huawei:euleros:2.0, p-cpe:/a:huawei:euleros:docker-engine

Required KB Items: Host/local_checks_enabled, Host/cpu, Host/EulerOS/release, Host/EulerOS/rpm-list, Host/EulerOS/sp

Excluded KB Items: Host/EulerOS/uvp_version

Exploit Available: true

Exploit Ease: Exploits are available

Patch Publication Date: 7/16/2024

Vulnerability Publication Date: 4/4/2023

Reference Information

CVE: CVE-2023-28840, CVE-2023-28841, CVE-2023-28842, CVE-2024-24557, CVE-2024-29018