National Instruments LabVIEW < 2024 Q3 Multiple Vulnerabilities

high Nessus Plugin ID 204716

Synopsis

An application installed on the remote Windows host is affected by multiple vulnerabilities.

Description

The version of National Instruments (NI) LabVIEW installed on the remote Windows host is affected by multiple vulnerabilities:

- An out of bounds read due to a missing bounds check in LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. (CVE-2024-4079)

- A memory corruption issue due to an improper length check in LabVIEW tdcore.dll may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI. This vulnerability affects LabVIEW 2024 Q1 and prior versions. (CVE-2024-4080)

- A memory corruption issue due to an improper length check in NI LabVIEW may disclose information or result in arbitrary code execution. Successful exploitation requires an attacker to provide a user with a specially crafted VI.
This vulnerability affects NI LabVIEW 2024 Q1 and prior versions. (CVE-2024-4081)

Note that Nessus has not tested for this issue but has instead relied only on the application's self-reported version number.

Solution

Upgrade to the NI LabVIEW version referenced in the vendor advisory

See Also

http://www.nessus.org/u?c18789b3

http://www.nessus.org/u?30427908

Plugin Details

Severity: High

ID: 204716

File Name: labview_2024_Q3.nasl

Version: 1.6

Type: local

Agent: windows

Family: Windows

Published: 7/25/2024

Updated: 9/13/2024

Supported Sensors: Nessus Agent, Nessus

Risk Information

VPR

Risk Factor: Medium

Score: 6.7

CVSS v2

Risk Factor: High

Base Score: 7.2

Temporal Score: 5.3

Vector: CVSS2#AV:L/AC:L/Au:N/C:C/I:C/A:C

CVSS Score Source: CVE-2024-4081

CVSS v3

Risk Factor: High

Base Score: 7.8

Temporal Score: 6.8

Vector: CVSS:3.0/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/a:ni:labview

Required KB Items: SMB/Registry/Enumerated, installed_sw/National Instruments LabVIEW

Exploit Ease: No known exploits are available

Patch Publication Date: 7/12/2024

Vulnerability Publication Date: 7/12/2024

Reference Information

CVE: CVE-2024-4079, CVE-2024-4080, CVE-2024-4081

IAVA: 2024-A-0444