Schneider Electric Accutech Manager Stack Exhaustion (CVE-2024-6918)

high Nessus Plugin ID 207348

Synopsis

An OT application is affected by a stack exhaustion vulnerability.

Description

The Schneider Electric Accutech Manager server running on the remote host is affected by a stack exhaustion vulnerability due to the lack of proper validation of a user-supplied data. An unauthenticated, remote attacker can exploit this, via a specially crafted message, to terminate the process.

Solution

Upgrade to version 2.10.0 or later.

See Also

http://www.nessus.org/u?869d9a81

Plugin Details

Severity: High

ID: 207348

File Name: schneider_electric_accutech_manager_cve-2024-6918.nbin

Version: 1.2

Type: remote

Family: SCADA

Published: 9/17/2024

Updated: 9/18/2024

Supported Sensors: Nessus

Risk Information

VPR

Risk Factor: Low

Score: 3.6

CVSS v2

Risk Factor: Medium

Base Score: 5

Temporal Score: 3.9

Vector: CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:P

CVSS Score Source: CVE-2024-6918

CVSS v3

Risk Factor: High

Base Score: 7.5

Temporal Score: 6.7

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Temporal Vector: CVSS:3.0/E:P/RL:O/RC:C

Vulnerability Information

CPE: cpe:/a:schneider-electric:accutech_manager

Required KB Items: installed_sw/Schneider Electric Accutech Manager Server

Exploit Available: true

Exploit Ease: Exploits are available

Exploited by Nessus: true

Patch Publication Date: 8/13/2024

Vulnerability Publication Date: 8/13/2024

Reference Information

CVE: CVE-2024-6918