Rockwell FactoryTalk Batch View < 3.00 Authentication Bypass

high Nessus Plugin ID 207520

Synopsis

An application installed on the remote Windows host is affected by a vulnerability.

Description

The version of Rockwell FactoryTalk Batch View installed on the remote Windows host is prior to 3.00. It is, therefore, affected by a vulnerability.

- An authentication bypass vulnerability exists in the affected product. The vulnerability exists due to shared secrets across accounts and could allow a threat actor to impersonate a user if the threat actor is able to enumerate additional information required during authentication. (CVE-2024-45823)

Note that Nessus has not tested for this issue but has instead relied only on the application's self-reported version number.

Solution

Upgrade to Rockwell FactoryTalk Batch View version 3.00 or later.

See Also

http://www.nessus.org/u?7f447a14

https://www.cisa.gov/news-events/ics-advisories/icsa-24-256-22

Plugin Details

Severity: High

ID: 207520

File Name: rockwell_factorytalk_batch_view_3_00.nasl

Version: 1.2

Type: local

Agent: windows

Family: SCADA

Published: 9/20/2024

Updated: 9/23/2024

Supported Sensors: Nessus Agent, Nessus

Risk Information

VPR

Risk Factor: Medium

Score: 6.7

CVSS v2

Risk Factor: High

Base Score: 7.6

Temporal Score: 5.6

Vector: CVSS2#AV:N/AC:H/Au:N/C:C/I:C/A:C

CVSS Score Source: CVE-2024-45823

CVSS v3

Risk Factor: High

Base Score: 8.1

Temporal Score: 7.1

Vector: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: x-cpe:/a:rockwellautomation:factorytalk_batch_view

Required KB Items: installed_sw/Rockwell FactoryTalk Batch View

Exploit Ease: No known exploits are available

Patch Publication Date: 9/12/2024

Vulnerability Publication Date: 9/12/2024

Reference Information

CVE: CVE-2024-45823

IAVA: 2024-A-0586

ICSA: 24-256-22