Pulse Connect Secure < 22.7R2.3 Multiple vulnerabilities

critical Nessus Plugin ID 212765

Synopsis

Pulse Connect Secure installed on the remote host is affected by multiple vulnerabilities.

Description

The Pulse Connect Secure installed on the remote host is prior to 22.7R2.3. It is, therefore, affected by multiple vulnerabilities.

- A heap-based buffer overflow in IPsec of Ivanti Connect Secure before version 22.7R2.3 allows a remote unauthenticated attacker to cause a denial of service. (CVE-2024-37377)

- Command injection in Ivanti Connect Secure before version 22.7R2.3 and Ivanti Policy Secure allows a remote authenticated attacker with admin privileges to achieve remote code (CVE-2024-11634)

Note that Nessus has not tested for this issue but has instead relied only on the application's self-reported version number.

Solution

Upgrade to Pulse Connect Secure 22.7R2.3 or later.

See Also

http://www.nessus.org/u?7e5dfedb

Plugin Details

Severity: Critical

ID: 212765

File Name: pulse_secure_desktop_client_22-7R2-3.nasl

Version: 1.2

Type: remote

Agent: windows

Family: Windows

Published: 12/13/2024

Updated: 12/16/2024

Supported Sensors: Nessus

Risk Information

VPR

Risk Factor: High

Score: 8.1

CVSS v2

Risk Factor: High

Base Score: 8.3

Temporal Score: 6.1

Vector: CVSS2#AV:N/AC:L/Au:M/C:C/I:C/A:C

CVSS Score Source: CVE-2024-11633

CVSS v3

Risk Factor: Critical

Base Score: 9.1

Temporal Score: 7.9

Vector: CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/a:pulsesecure:pulse_secure_desktop_client

Required KB Items: installed_sw/Pulse Connect Secure

Exploit Ease: No known exploits are available

Patch Publication Date: 12/10/2024

Vulnerability Publication Date: 12/10/2024

Reference Information

CVE: CVE-2024-11633, CVE-2024-9844

IAVA: 2024-A-0800