EMC RepliStor < 6.2 SP5/6.3 SP2 Multiple Heap Overflows

critical Nessus Plugin ID 38206

Synopsis

The remote software is affected by multiple vulnerabilities.

Description

According to its version, the installation of EMC RepliStor Server on the remote host is earlier than version 6.2 SP5 or 6.3 SP2. Such versions are affected by multiple heap overflow vulnerabilities. By sending specially crafted requests to either 'ctrlservice.exe' or 'rep_srv.exe', an unauthorized attacker could execute arbitrary code on the remote system with SYSTEM level privileges.

Solution

Upgrade to RepliStor 6.2 SP5 / 6.3 SP2 or later.

See Also

http://www.fortiguardcenter.com/advisory/FGA-2009-13.html

http://www.nessus.org/u?1c89e2a9

http://www.nessus.org/u?b7a129da

Plugin Details

Severity: Critical

ID: 38206

File Name: emc_replistor_heap_overflows.nasl

Version: 1.9

Type: remote

Published: 4/29/2009

Updated: 7/10/2018

Supported Sensors: Nessus

Risk Information

VPR

Risk Factor: Medium

Score: 5.9

CVSS v2

Risk Factor: Critical

Base Score: 10

Temporal Score: 7.4

Vector: CVSS2#AV:N/AC:L/Au:N/C:C/I:C/A:C

Vulnerability Information

Required KB Items: EMC/RepliStor/Version

Exploit Ease: No known exploits are available

Reference Information

CVE: CVE-2009-1119

BID: 34449

CWE: 119

Secunia: 34699