Siemens SIMATIC S7-1500, SIMATIC S7-1500 Software Controller and SIMATIC ET 200SP OpenController Improper Input Validation (CVE-2018-13805)

high Tenable OT Security Plugin ID 500173

Synopsis

The remote OT asset is affected by a vulnerability.

Description

A vulnerability has been identified in SIMATIC ET 200SP Open Controller (All versions >= V2.0 and < V2.1.6), SIMATIC S7-1500 Software Controller (All versions >= V2.0 and < V2.5), SIMATIC S7-1500 incl. F (All versions >= V2.0 and < V2.5). An attacker can cause a denial-of-service condition on the network stack by sending a large number of specially crafted packets to the PLC. The PLC will lose its ability to communicate over the network. This vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no privileges and no user interaction. An attacker could use this vulnerability to compromise availability of the network connectivity. At the time of advisory publication no public exploitation of this vulnerability was known.

This plugin only works with Tenable.ot. Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

The following text was originally created by the Cybersecurity and Infrastructure Security Agency (CISA). The original can be found at CISA.gov.

Siemens provides updates to address this vulnerability in these products and recommends users update to the new version.

- SIMATIC S7-1500 Software Controller: Update to v2.5 or newer:

https://support.industry.siemens.com/cs/us/en/view/109478528

- SIMATIC S7-1500 incl. F: Update to v2.5 or newer:

https://support.industry.siemens.com/cs/us/en/ps/13717/dl

- SIMATIC ET-200SP Open Controller: Update to v2.1.6 or newer:

https://support.industry.siemens.com/cs/us/en/view/109759122

Siemens has identified the following specific workarounds and mitigations users can apply to reduce the risk:

- Restrict network access to affected devices
- Apply cell-protection concept
- Apply defense-in-depth

As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens’ operational guidelines for industrial security (https://www.siemens.com/cert/operational-guidelines-industrial-security), and following the recommendations in the product manuals.

Additional information on Industrial Security by Siemens can be found at:

https://www.siemens.com/industrialsecurity

For more information on this vulnerability and associated software updates, please see Siemens security advisory SSA-347726 on their website:

https://www.siemens.com/cert/advisories

See Also

https://cert-portal.siemens.com/productcert/pdf/ssa-347726.pdf

https://www.cisa.gov/news-events/ics-advisories/icsa-18-282-05

Plugin Details

Severity: High

ID: 500173

Version: 1.7

Type: remote

Family: Tenable.ot

Published: 2/7/2022

Updated: 9/4/2024

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Low

Score: 3.6

CVSS v2

Risk Factor: Medium

Base Score: 5

Temporal Score: 3.7

Vector: CVSS2#AV:N/AC:L/Au:N/C:N/I:N/A:P

CVSS Score Source: CVE-2018-13805

CVSS v3

Risk Factor: High

Base Score: 7.5

Temporal Score: 6.5

Vector: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:simatic_et_200sp_firmware, cpe:/o:siemens:simatic_s7-1500f_firmware, cpe:/o:siemens:simatic_s7-1500_firmware

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 10/10/2018

Vulnerability Publication Date: 10/10/2018

Reference Information

CVE: CVE-2018-13805

CWE: 400

ICSA: 18-282-05