Siemens SCALANCE M875 Insufficiently Protected Credentials (CVE-2018-11449)

high Tenable OT Security Plugin ID 500999

Synopsis

The remote OT asset is affected by a vulnerability.

Description

A vulnerability has been identified in SCALANCE M875 (All versions).
An attacker with access to the local file system might obtain passwords for administrative users. Successful exploitation requires read access to files on the local file system. A successful attack could allow an attacker to obtain administrative passwords. At the time of advisory publication no public exploitation of this security vulnerability was known.

This plugin only works with Tenable.ot.
Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://cert-portal.siemens.com/productcert/pdf/ssa-977428.pdf

Plugin Details

Severity: High

ID: 500999

Version: 1.2

Type: remote

Family: Tenable.ot

Published: 4/11/2023

Updated: 8/24/2023

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Medium

Score: 5.9

CVSS v2

Risk Factor: Low

Base Score: 2.1

Temporal Score: 1.6

Vector: CVSS2#AV:L/AC:L/Au:N/C:P/I:N/A:N

CVSS Score Source: CVE-2018-11449

CVSS v3

Risk Factor: High

Base Score: 7.8

Temporal Score: 6.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/o:siemens:scalance_m875_firmware:-

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 6/26/2018

Vulnerability Publication Date: 6/26/2018

Reference Information

CVE: CVE-2018-11449