Siemens InsydeH2O Classic Buffer Overflow (CVE-2022-24350)

medium Tenable OT Security Plugin ID 501726

Synopsis

The remote OT asset is affected by a vulnerability.

Description

An issue was discovered in IhisiSmm in Insyde InsydeH2O with kernel 5.0 through 5.5. IHISI function 0x17 verifies that the output buffer lies within the command buffer but does not verify that output data does not go beyond the end of the command buffer. In particular, the GetFlashTable function is called directly on the Command Buffer before the DataSize is check, leading to possible circumstances where the data immediately following the command buffer could be destroyed before returning a buffer size error.

Insyde BIOS is typically used in RUGGEDCOM APE products and some SIMATIC devices. Please refer to the vendor advisory for a precise list of models concerned.

This plugin only works with Tenable.ot Please visit https://www.tenable.com/products/tenable-ot for more information.

Solution

Refer to the vendor advisory.

See Also

https://www.insyde.com/security-pledge/SA-2023027

https://www.insyde.com/security-pledge

Plugin Details

Severity: Medium

ID: 501726

Version: 1.1

Type: remote

Family: Tenable.ot

Published: 9/26/2023

Updated: 9/27/2023

Supported Sensors: Tenable OT Security

Risk Information

VPR

Risk Factor: Low

Score: 3.6

CVSS v2

Risk Factor: Medium

Base Score: 4.6

Temporal Score: 3.4

Vector: CVSS2#AV:L/AC:L/Au:S/C:N/I:C/A:N

CVSS Score Source: CVE-2022-24350

CVSS v3

Risk Factor: Medium

Base Score: 5.5

Temporal Score: 4.8

Vector: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N

Temporal Vector: CVSS:3.0/E:U/RL:O/RC:C

Vulnerability Information

CPE: cpe:/a:insyde:insydeh2o

Required KB Items: Tenable.ot/Siemens

Exploit Ease: No known exploits are available

Patch Publication Date: 4/12/2023

Vulnerability Publication Date: 4/12/2023

Reference Information

CVE: CVE-2022-24350

CWE: 120